Yeoman and servicing Instrukcja Obsługi Strona 39

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 44
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 38
39
SERVICING INSTRUCTIONS
REPLACING PARTS
11.4 After replacing the control box ensure all cables and
connections are refitted as detailed in Diagram 28.
AR2660a
Touch Pad
Supply Cable
Battery Power
Supply
Touch Pad
Control
Ignition Lead
28
Stepper Motor Cable
Pilot Pipe
Thermocouple
Earth Lead
Interrupter Leads
11.5 Prior to re-connection of the control box to the appliance, if
there is no communication between the remote handset
and the appliance, or if the handset is replaced, it will be
necessary to pair the (new) handset with the appliance.
11.6 Ensure batteries are fitted and working in the handset.
11.7 Re-fit the touch pad control cable and the battery power
supply cable to the control box.
11.8 Press the On/Off button () for at least 10 seconds. The
LED will flash on and off as normal during this time. When
the LED on the control lights up for at least 1 second
release the button.
11.9 Within 5 seconds of the LED going out press the () button
followed directly by the () button.
11.10 Within 20 seconds press the yellow button on the control
box (see Diagram 17). This may be easier using a pencil,
ball point pen or similar.
11.11 The control box will beep to confirm the pairing operation
has been successful.
If there are any difficulties achieving pairing ensure that
the handset is set to Channel A. To do this follow the
steps below:
11.12 Press the On/Off button () for at least 10 seconds. The
LED will flash on and off as normal during this time. When
the LED on the control lights up for at least 1 second
release the button.
11.13 Within 5 seconds of the LED going out press the OK button
and then press the () button.
11.14 Disconnect the batteries from the control box and
reconnect after 10 seconds. The handset will now be set to
Channel A.
11.15 Attempt the pairing again following the steps below:
NOTE: These steps differ from the previous.
11.16 Press the On/Off button () for at least 10 seconds. The
LED will flash on and off as normal during this time. When
the LED on the control lights up for at least 1 second
release the button.
11.17 Within 5 seconds of the LED going out press the () button
followed directly by the () button.
11.18 Disconnect the battery pack from the control box and
reconnect after 10 seconds.
11.19 The motor on the valve will turn. Once it has stopped
repeatedly press and release the yellow button on the
control box until the control box beeps to confirm the
pairing operation has been successful.
12. MAIN INJECTOR
12.1 Turn the gas supply off at the isolation device. Refer to
Section 5, Replacing Parts to remove the main burner.
12.2 Undo the compression nut from the feed pipe at the gas
control under the appliance.
12.3 Working from inside the firebox, remove the lock nut from
the injector, see Diagram 29 and withdraw the injector
complete with the feed pipe from under the appliance.
AR0918
29
12.4 Holding the injector with a spanner, undo the feed pipe.
NOTE: THE ORIENTATION OF THE INJECTOR.
12.5 Reassemble in reverse order, turn on the gas supply and
check for any leaks.
Przeglądanie stron 38